X1-HAC-4 / X1-HAC-7 / X3-HAC-11 / X3-HAC-22
4.6 kW / 7.2 kW / 11 kW / 22 kW
RFID management function
Schedule time charging
Capable of 100% green energy
Automatic switch between one and three-phase
Current leakage protection (30mA AC & 6mA DC)
Smart dynamic load balance control
Integrate with new/existing PV systems
Support multiple communication protocols
SolaX Smart EV Charger G2 is leading the charge in revolutionizing the electric vehicle (EV) charging landscape, offering cutting-edge solutions to meet the surging demand for sustainable transportation. With its advanced features and robust performance, SolaX Smart EV Charger G2 is paving the way for a cleaner and greener future.
Catalog | Specification | X1-HAC-4 |
AC Nominal Input | Voltage [V] | 230 |
Frequency [Hz] | 50/60 | |
Grid Earth Type | TN, TT, IT | |
AC Nominal Output | Voltage [V] | 230 |
Current [A] | 6-20 (single phase) | |
Power [kW] | 1.4-4.6 | |
Interface & Communication | Communication interface | Wifi/Ethernet/4G (Optional)/RS 485*2 |
Protocol | OCPP 1.6j, Modbus TCP, Modbus RTU, Cloud API | |
Communicate | IEC 61851-1, ISO 15118 (Optional) | |
Authentication | Plug&Charge/RFID (ISO-14443-A)/APP | |
MID meter | External(Optional) | |
HMI | RGB LED / APP / LCD(Optional) | |
Remote control | APP&Web | |
Application | Residential/Destination place/Public | |
General Data | Housing material | PC |
Installation method | Wall/Pedestal(Optional) | |
Charging outlet | Type2 Plug/Type2 Socket (IEC 62196) | |
Cable length(m) | 6.5m(Type P) | |
Operating Temperature(°C) | -30~50 | |
Storage Temperature(°C) | -40~60 | |
Working humidity(%) | 5%~95% without condensation | |
Working altitude(m) | 2000m | |
Degree of Protection | IP65 (For plug type) / IP54 (For socket type) / K10 (Housing) / IK08(Screen) | |
Cooling method | Nature cooling | |
Application site | Indoor/Outdoor | |
Weight [kg] | 5kg for Plug Type | |
Dimension(WxHxD) [mm] | 390x206x139mm | |
Security Protection | Multiple Protection | Over/Under voltage protection, Overload protection, Shortcircuit protection, Current leakage protection, Grounding protection, Surge protection, Overtemperature protection |
Integral Earth Leakage Protection | Integrated current failure monitoring (30mA AC & 6mA DC) | |
Cable protection | Cable Lock (APP control) | |
Relay protection | Relay weld detection | |
Built-in PEN fault technology | According to BS 7671:2018 requirements* | |
Standard | IEC 61851-1:2017, IEC 62196-2:2016 |
Catalog | Specification | X1-HAC-7 |
AC Nominal Input | Voltage [V] | 230 |
Frequency [Hz] | 50/60 | |
Grid Earth Type | TN, TT, IT | |
AC Nominal Output | Voltage [V] | 230 |
Current [A] | 6-32 (single phase) | |
Power [kW] | 1.4-7.2 | |
Interface & Communication | Communication interface | Wifi/Ethernet/4G (Optional)/RS 485*2 |
Protocol | OCPP 1.6j, Modbus TCP, Modbus RTU, Cloud API | |
Communicate | IEC 61851-1, ISO 15118 (Optional) | |
Authentication | Plug&Charge/RFID (ISO-14443-A)/APP | |
MID meter | External(Optional) | |
HMI | RGB LED / APP / LCD(Optional) | |
Remote control | APP&Web | |
Application | Residential/Destination place/Public | |
General Data | Housing material | PC |
Installation method | Wall/Pedestal(Optional) | |
Charging outlet | Type2 Plug/Type2 Socket (IEC 62196) | |
Cable length(m) | 6.5(Type P) | |
Operating Temperature(°C) | -30~50 | |
Storage Temperature(°C) | -40~60 | |
Working humidity(%) | 5%~95% without condensation | |
Working altitude(m) | 2000 | |
Degree of Protection | IP65 (For plug type)/IP54 (For socket type) IK10 (Housing) / IK08(Screen) | |
Cooling method | Nature cooling | |
Application site | Indoor/Outdoor | |
Weight [kg] | 3 for Socket Type 5 for Plug Type | |
Dimension(WxHxD) [mm] | 390x206x139 | |
Security Protection | Multiple Protection | Over/Under voltage protection,Overload protection,Shortcircuit protection, Current leakage protection,Grounding protection,Surge protection, Overtemperature protection |
Integral Earth Leakage Protection | Integrated current failure monitoring (30mA AC & 6mA DC) | |
Cable protection | Cable Lock (APP control) | |
Relay protection | Relay weld detection | |
Built-in PEN fault technology | According to BS 7671:2018 requirements* | |
Standard | IEC 61851-1:2017, IEC 62196-2:2016 |
Catalog | Specification | X3-HAC-11 |
AC Nominal Input | Voltage [V] | 400 |
Frequency [Hz] | 50/60 | |
Grid Earth Type | TN,TT,IT | |
AC Nominal Output | Voltage [V] | 400 |
Current [A] | 6-16 (single phase) | |
Power [kW] | 1.4-11 | |
Interface & Communication | Communication interface | Wifi/Ethernet/4G (Optional)/RS 485*2 |
Protocol | OCPP 1.6j, Modbus TCP, Modbus RTU, Cloud API | |
Communicate | IEC 61851-1, ISO 15118 (Optional) | |
Authentication | Plug&Charge/RFID (ISO-14443-A)/APP | |
MID meter | External(Optional) | |
HMI | RGB LED / APP / LCD(Optional) | |
Remote control | APP&Web | |
Application | Residential/Destination place/Public | |
General Data | Housing material | PC |
Installation method | Wall/Pedestal(Optional) | |
Charging outlet | Type2 Plug/Type2 Socket (IEC 62196) | |
Cable length(m) | 6.5(Type P) | |
Operating Temperature(°C) | -30~50 | |
Storage Temperature(°C) | -40~60 | |
Working humidity(%) | 5%~95% without condensation | |
Working altitude(m) | 2000 | |
Degree of Protection | IP65 (For plug type)/IP54 (For socket type) IK10 (Housing) / IK08(Screen) | |
Cooling method | Nature cooling | |
Application site | Indoor/Outdoor | |
Weight [kg] | 3 for Socket Type 6.5 for Plug Type | |
Dimension(WxHxD) [mm] | 390x206x139 | |
Security Protection | Multiple Protection | Over/Under voltage protection,Overload protection,Shortcircuit protection, Current leakage protection,Grounding protection,Surge protection, Overtemperature protection |
Integral Earth Leakage Protection | Integrated current failure monitoring (30mA AC & 6mA DC) | |
Cable protection | Cable Lock (APP control) | |
Relay protection | Relay weld detection | |
Built-in PEN fault technology | According to BS 7671:2018 requirements* | |
Standard | IEC 61851-1:2017, IEC 62196-2:2016 |
Catalog | Specification | X3-HAC-22 |
AC Nominal Input | Voltage [V] | 400 |
Frequency [Hz] | 50/60 | |
Grid Earth Type | TN,TT,IT | |
AC Nominal Output | Voltage [V] | 400 |
Current [A] | 6-32 (single phase) | |
Power [kW] | 1.4-22 | |
Interface & Communication | Communication interface | Wifi/Ethernet/4G (Optional)/RS 485*2 |
Protocol | OCPP 1.6j, Modbus TCP, Modbus RTU, Cloud API | |
Communicate | IEC 61851-1, ISO 15118 (Optional) | |
Authentication | Plug&Charge/RFID (ISO-14443-A)/APP | |
MID meter | External(Optional) | |
HMI | RGB LED / APP / LCD(Optional) | |
Remote control | APP&Web | |
Application | Residential/Destination place/Public | |
General Data | Housing material | PC |
Installation method | Wall/Pedestal(Optional) | |
Charging outlet | Type2 Plug/Type2 Socket (IEC 62196) | |
Cable length(m) | 6.5(Type P) | |
Operating Temperature(°C) | -30~50 | |
Storage Temperature(°C) | -40~60 | |
Working humidity(%) | 5%~95% without condensation | |
Working altitude(m) | 2000 | |
Degree of Protection | IP65 (For plug type)/IP54 (For socket type) IK10 (Housing) / IK08(Screen) | |
Cooling method | Nature cooling | |
Application site | Indoor/Outdoor | |
Weight [kg] | 3 for Socket Type 6.5 for Plug Typ | |
Dimension(WxHxD) [mm] | 390x206x139 | |
Security Protection | Multiple Protection | Over/Under voltage protection,Overload protection,Shortcircuit protection, Current leakage protection,Grounding protection,Surge protection, Overtemperature protection |
Integral Earth Leakage Protection | Integrated current failure monitoring (30mA AC & 6mA DC) | |
Cable protection | Cable Lock (APP control) | |
Relay protection | Relay weld detection | |
Built-in PEN fault technology | According to BS 7671:2018 requirements* | |
Standard | IEC 61851-1:2017, IEC 62196-2:2016 |