SolaX Power Network Technology (Zhejiang) Co.,Ltd.
SolaX Power Network Technology (Zhejiang) Co.,Ltd.
ENGLISH(GLOBAL)
micro-4-in-1-3
micro-4-in-1-1
micro-4-in-1-2

X1 Micro 4 in 1

X1 Micro 4 in 1

1300W/ 1500W / 1600W / 1800W / 2000W / 2200W

Flexible Adaptability

  • Easy and flexible expansion of system capacity
  • Support AC coupling solution
  • Support 1-phase microinverter integration into 3-phase power grids*


High Efficiency

  • Max. 2400VA output power
  • Max. 19.5A DC input current
  • Four MPPT channels, small size, light weight


Assured Safety

  • Built-in Rapid Shutdown compliant
  • Safety protection relay integrated
  • IP67 protection degree


Intelligent Design

  • Reactive power control
  • Built-in industrial grade Wi-Fi module
  • Easy to install and maintain


Why X1 Micro 4 in 1

The SolaX X1-Micro series of microinverters stands out as one of the most powerful options in the 4-in-1 microinverter category, boasting an impressive output power of up to 2200 VA. These cutting-edge products are specifically designed to handle the latest and previous generation of high power modules with 4 independent MPPTs, allowing for substantial input current and output power capabilities. The integration of a reliable WiFi wireless solution ensures consistent and dependable communication functionality. Offering a cost-effective solution for both residential and commercial solar applications, these microinverters are fully compatible with SolaX Hybrid systems and can also be seamlessly integrated into AC coupled systems on the market.

X1-Micro 1300
X1-Micro 1500
X1-Micro 1600
X1-Micro 1800
X1-Micro 2000
X1-Micro 2200
X1-Micro 2400
DC INPUT
Commonly used module/power per input300 ~ 505+ W
Max. PV input voltage60 V
MPPT voltage range22 ~ 60 V
Start-up voltage20 V
Max. PV input current4 × 12 A
Max. input short circuit current4 × 20 A
No. of MPP trackers4
Strings per MPP tracker1
AC OUTPUT
Rated AC output power1300 VA
Maximum continuous output power1300 VA
Maximum continuous output current5.91 A @220 V

5.56 A @230 V

5.42 A @240 V
Rated grid voltage/range1 / N / PE, 220 / 230 / 240 V
Nominal AC voltage range180 ~ 264 V
Nominal AC frequency50 Hz / 60 Hz
AC frequency / range50 ± 5 Hz / 60 ± 5 Hz
Maximum units per 10AWG branch*4@220 V

4@230 V

5@240 V
Maximum units per 12AWG branch*3@220 V

3@230 V

4@240 V
Power Factor range~ 1 (0.8 lagging to 0.8 leading)
THDi (Rated power)< 3%


DC INPUT
Commonly used module/power per input320 ~ 540+ W
Max. PV input voltage60 V
MPPT voltage range22 ~ 60 V
Start-up voltage20 V
Max. PV input current4 × 14 A
Max. input short circuit current4 × 20 A
No. of MPP trackers4
Strings per MPP tracker1
AC OUTPUT
Rated AC output power1500 VA
Maximum continuous output power1500 VA
Maximum continuous output current6.82 A @220 V

6.53 A @230 V

6.25 A @240 V
Rated grid voltage/range1 / N / PE, 220 / 230 / 240 V
Nominal AC voltage range180 ~ 264 V
Nominal AC frequency50 Hz / 60 Hz
AC frequency / range50 ± 5 Hz / 60 ± 5 Hz
Maximum units per 10AWG branch*4@220 V

4@230 V

4@240 V
Maximum units per 12AWG branch*3@220 V

3@230 V

3@240 V
Power Factor range~ 1 (0.8 lagging to 0.8 leading)
THDi (Rated power)< 3%


DC INPUT
Commonly used module/power per input360 ~ 600+ W
Max. PV input voltage60 V
MPPT voltage range22 ~ 60 V
Start-up voltage20 V
Max. PV input current4 × 15 A
Max. input short circuit current4 × 20 A
No. of MPP trackers4
Strings per MPP tracker1
AC OUTPUT
Rated AC output power1600 VA
Maximum continuous output power1600 VA
Maximum continuous output current7.28 A @220 V

6.96 A @230 V

6.67 A @240 V
Rated grid voltage/range1 / N / PE, 220 / 230 / 240 V
Nominal AC voltage range180 ~ 264 V
Nominal AC frequency50 Hz / 60 Hz
AC frequency / range50 ± 5 Hz / 60 ± 5 Hz
Maximum units per 10AWG branch*4@220 V

4@230 V

4@240 V
Maximum units per 12AWG branch*3@220 V

3@230 V

3@240 V
Power Factor range~ 1 (0.8 lagging to 0.8 leading)
THDi (Rated power)< 3%


DC INPUT
Commonly used module/power per input400 ~ 600+ W
Max. PV input voltage60 V
MPPT voltage range22 ~ 60 V
Start-up voltage20 V
Max. PV input current4 × 16 A
Max. input short circuit current4 × 20 A
No. of MPP trackers4
Strings per MPP tracker1
AC OUTPUT
Rated AC output power1800 VA
Maximum continuous output power1800 VA
Maximum continuous output current8.19 A @220 V

7.83 A @230 V

7.50 A @240 V
Rated grid voltage/range1 / N / PE, 220 / 230 / 240 V
Nominal AC voltage range180 ~ 264 V
Nominal AC frequency50 Hz / 60 Hz
AC frequency / range50 ± 5 Hz / 60 ± 5 Hz
Maximum units per 10AWG branch*3@220 V

3@230 V

3@240 V
Maximum units per 12AWG branch*2@220 V

2@230 V

2@240 V
Power Factor range~ 1 (0.8 lagging to 0.8 leading)
THDi (Rated power)< 3%


DC INPUT
Commonly used module/power per input400 ~ 670+ W
Max. PV input voltage60 V
MPPT voltage range22 ~ 60 V
Start-up voltage20 V
Max. PV input current4 × 18 A
Max. input short circuit current4 × 20 A
No. of MPP trackers4
Strings per MPP tracker1
AC OUTPUT
Rated AC output power2000 VA
Maximum continuous output power2000 VA
Maximum continuous output current9.10 A @220 V

8.70 A @230 V

8.34 A @240 V
Rated grid voltage/range1 / N / PE, 220 / 230 / 240 V
Nominal AC voltage range180 ~ 264 V
Nominal AC frequency50 Hz / 60 Hz
AC frequency / range50 ± 5 Hz / 60 ± 5 Hz
Maximum units per 10AWG branch*3@220 V

3@230 V

3@240 V
Maximum units per 12AWG branch*2@220 V

2@230 V

2@240 V
Power Factor range~ 1 (0.8 lagging to 0.8 leading)
THDi (Rated power)< 3%


DC INPUT
Commonly used module/power per input400 ~ 670+ W
Max. PV input voltage60 V
MPPT voltage range22 ~ 60 V
Start-up voltage20 V
Max. PV input current4 × 19.5 A
Max. input short circuit current4 × 20 A
No. of MPP trackers4
Strings per MPP tracker1
AC OUTPUT
Rated AC output power2200 VA
Maximum continuous output power2200 VA
Maximum continuous output current10.00 A @220 V

9.57 A @230 V

9.17 A @240 V
Rated grid voltage/range1 / N / PE, 220 / 230 / 240 V
Nominal AC voltage range180 ~ 264 V
Nominal AC frequency50 Hz / 60 Hz
AC frequency / range50 ± 5 Hz / 60 ± 5 Hz
Maximum units per 10AWG branch*3@220 V

3@230 V

3@240 V
Maximum units per 12AWG branch*2@220 V

2@230 V

2@240 V
Power Factor range~ 1 (0.8 lagging to 0.8 leading)
THDi (Rated power)< 3%


DC INPUT
Commonly used module/power per input400 ~ 670+ W
Max. PV input voltage60 V
MPPT voltage range22 ~ 60 V
Start-up voltage20 V
Max. PV input current4 × 19.5 A
Max. input short circuit current4 × 20 A
No. of MPP trackers4
Strings per MPP tracker1
AC OUTPUT
Rated AC output power2400 VA
Maximum continuous output power2200 VA
Maximum continuous output current10.91 A @220 V

10.43 A @230 V

10.00 A @240 V
Rated grid voltage/range1 / N / PE, 220 / 230 / 240 V
Nominal AC voltage range180 ~ 264 V
Nominal AC frequency50 Hz / 60 Hz
AC frequency / range50 ± 5 Hz / 60 ± 5 Hz
Maximum units per 10AWG branch*2@220 V

2@230 V

3@240 V
Maximum units per 12AWG branch*2@220 V

2@230 V

2@240 V
Power Factor range~ 1 (0.8 lagging to 0.8 leading)
THDi (Rated power)< 3%


Related Products
Documents
Datasheet
English
Language
English
Format
PDF
Size
682KB
Last updated
21/04/2025
Inquiry us
SolaX Power Network Technology (Zhejiang) Co.,Ltd.
We use cookies to optimise and personalise your experience, but you can choose to opt out of non-essential cookies.
To find out more, read our Privacy Policy and Terms of Use
Reject All
Accept All
Leave Your Message