X3-FORTH PLUS.png
Three Phase Inverter

X3 FORTH PLUS

X3-FORTH PLUS

120kW / 125kW / 136kW / 150kW

Intelligent Design


  • Fan self-cleaning function for easier maintenance

  • Night-time SVG voltage regulation support

  • AC terminal over temperature detection


Flexible Adaptability


  • 6 MPPTs, 4 strings per MPPT for precise power

  • Reliable up to 5000m altitude

  • Power line communication (PLC) (Optional)*

  • Buil-in Anti-PID Protection* (Optional)




Assured Safety


  • IP66 protection degree

  • AFCI support (optional)

  • Remote settings and upgrades

  • 24-hour monitoring

  • Automatic tripping DC switch

  • Type II SPD on AC&DC side (Optional)



High Efficiency


  • Up to 99% efficiency

  • 200% PV oversizing

  • 180~1000V, up to 65A per MPPT

  • Maintains full power up to 50°C, with operation

  • range from -25°C to +60°C


Why X3-FORTH PLUS

SolaX X3-FORTH PLUS offers up to 99% efficiency, durable performance in extreme temperatures, and flexible PV oversizing. It includes advanced safety features like IP66 protection and optional AFCI, alongside intelligent design functions like fan self-cleaning. Ideal for high-altitude use, with optional PLC and Anti-PID protection.

X3-FTH-120K-P
X3-FTH-125K-P
X3-FTH-136K-P
X3-FTH-150K-P
SpecificationsX3-FTH-120K-P
Max. recommended PV array power180.0 kWp
Max. PV input voltage1100 V
Nominal PV input voltage580 V / 600 V
Operating voltage range200 ~ 1000 V
MPPT voltage range180 ~ 1000 V
Start-up voltage200 V
No. of MPP trackers / Strings per MPP tracker6 / 4
Max. input current per MPPT65 A
Max. input short circuit current per MPPT82 A
Rated output power120 kW
Rated output current181.8 A / 174 A
Max. output apparent power132 kVA
Max. output continuous current200.6 A @ 380 V
Max. short circuit current500 A
Nominal AC voltage3 / (N) / PE, 220 / 380 V, 230 / 400 V
Nominal AC frequency50 Hz / 60 Hz
AC frequency range50 ± 5 Hz / 60 ± 5 Hz
Adjustable Power Factor range~ 1 (0.8 lagging to 0.8 leading)
THDI (rated power)< 3%
Max. efficiency98.6%
European efficiency98.2%
Ingress protectionIP66
Operating ambient temperature range-25 ~ 60°C
Max. operating altitude5000m (derating above 4000m)
Relative humidity0 ~ 100% RH (condensing)
Overvoltage CategoryMains: III, PV: II
Dimensions (W x H x D)1082 x 724 x 373 mm
Net weight99.8 kg
Cooling conceptSmart cooling
Communication interfacesRS485, Optional: PLC, Pocket WiFi / LAN / 4G
Power consumption (night)< 10 W
TopologyNon-isolated
Certificates and approvalsIEC 61727, IEC 62116, VDE4110, VDE4105, EN50459, NRS097, G99, RD1699, PPDS2020, CEI0-21, CEI0-16, VFR 2019




SpecificationsX3-FTH-125K-P
Max. recommended PV array power187.5 kWp
Max. PV input voltage1100 V
Nominal PV input voltage580 V / 600 V
Operating voltage range200 ~ 1000 V
MPPT voltage range180 ~ 1000 V
Start-up voltage200 V
No. of MPP trackers / Strings per MPP tracker6 / 4
Max. input current per MPPT65 A
Max. input short circuit current per MPPT82 A
Rated output power125 kW
Rated output current189.4 A / 181.2 A
Max. output apparent power137.5 kVA
Max. output continuous current209 A @ 380 V
Max. short circuit current500 A
Nominal AC voltage3 / (N) / PE, 220 / 380 V, 230 / 400 V
Nominal AC frequency50 Hz / 60 Hz
AC frequency range50 ± 5 Hz / 60 ± 5 Hz
Adjustable Power Factor range~ 1 (0.8 lagging to 0.8 leading)
THDI (rated power)< 3%
Max. efficiency98.6%
European efficiency98.2%
Ingress protectionIP66
Operating ambient temperature range-25 ~ 60°C
Max. operating altitude5000m (derating above 4000m)
Relative humidity0 ~ 100% RH (condensing)
Overvoltage CategoryMains: III, PV: II
Dimensions (W x H x D)1082 x 724 x 373 mm
Net weight99.8 kg
Cooling conceptSmart cooling
Communication interfacesRS485, Optional: PLC, Pocket WiFi / LAN / 4G
Power consumption (night)< 10 W
TopologyNon-isolated
Certificates and approvalsIEC 61727, IEC 62116, VDE4110, VDE4105, EN50459, NRS097, G99, RD1699, PPDS2020, CEI0-21, CEI0-16, VFR 2019




SpecificationsX3-FTH-136K-P
Max. recommended PV array power204 kWp
Max. PV input voltage1100 V
Nominal PV input voltage580 V / 600 V
Operating voltage range200 ~ 1000 V
MPPT voltage range180 ~ 1000 V
Start-up voltage200 V
No. of MPP trackers / Strings per MPP tracker6 / 4
Max. input current per MPPT65 A
Max. input short circuit current per MPPT82 A
Rated output power136 kW
Rated output current206.6 A / 196.3 A
Max. output apparent power150 kVA
Max. output continuous current228 A @ 380 V
Max. short circuit current500 A
Nominal AC voltage3 / (N) / PE, 220 / 380 V, 230 / 400 V
Nominal AC frequency50 Hz / 60 Hz
AC frequency range50 ± 5 Hz / 60 ± 5 Hz
Adjustable Power Factor range~ 1 (0.8 lagging to 0.8 leading)
THDI (rated power)< 3%
Max. efficiency98.6%
European efficiency98.2%
Ingress protectionIP66
Operating ambient temperature range-25 ~ 60°C
Max. operating altitude5000m (derating above 4000m)
Relative humidity0 ~ 100% RH (condensing)
Overvoltage CategoryMains: III, PV: II
Dimensions (W x H x D)1082 x 724 x 373 mm
Net weight99.8 kg
Cooling conceptSmart cooling
Communication interfacesRS485, Optional: PLC, Pocket WiFi / LAN / 4G
Power consumption (night)< 10 W
TopologyNon-isolated
Certificates and approvalsIEC 61727, IEC 62116, VDE4110, VDE4105, EN50459, NRS097, G99, RD1699, PPDS2020, CEI0-21, CEI0-16, VFR 2019




SpecificationsX3-FTH-150K-P
Max. recommended PV array power225 kWp
Max. PV input voltage1100 V
Nominal PV input voltage580 V / 600 V
Operating voltage range200 ~ 1000 V
MPPT voltage range180 ~ 1000 V
Start-up voltage200 V
No. of MPP trackers / Strings per MPP tracker6 / 4
Max. input current per MPPT65 A
Max. input short circuit current per MPPT82 A
Rated output power150 kW
Rated output current227.3 A / 217.4 A
Max. output apparent power165 kVA
Max. output continuous current250.7 A @ 380 V
Max. short circuit current500 A
Nominal AC voltage3 / (N) / PE, 220 / 380 V, 230 / 400 V
Nominal AC frequency50 Hz / 60 Hz
AC frequency range50 ± 5 Hz / 60 ± 5 Hz
Adjustable Power Factor range~ 1 (0.8 lagging to 0.8 leading)
THDI (rated power)< 3%
Max. efficiency98.6%
European efficiency98.2%
Ingress protectionIP66
Operating ambient temperature range-25 ~ 60°C
Max. operating altitude5000m (derating above 4000m)
Relative humidity0 ~ 100% RH (condensing)
Overvoltage CategoryMains: III, PV: II
Dimensions (W x H x D)1082 x 724 x 373 mm
Net weight99.8 kg
Cooling conceptSmart cooling
Communication interfacesRS485, Optional: PLC, Pocket WiFi / LAN / 4G
Power consumption (night)< 10 W
TopologyNon-isolated
Certificates and approvalsIEC 61727, IEC 62116, VDE4110, VDE4105, EN50459, NRS097, G99, RD1699, PPDS2020, CEI0-21, CEI0-16, VFR 2019




X3-FORTH PLUS
Documents
Inquiry us
SolaX Power Network Technology (Zhejiang) Co.,Ltd.
We use cookies to optimise and personalise your experience, but you can choose to opt out of non-essential cookies.
To find out more, read our Privacy Policy and Terms of Use
Reject All
Accept All
Leave Your Message