Single Phase Inverter

X1-SMART G2

  • 5kW / 6kW / 7kW / 8kW / 9kW /10kW

The X1-SMART G2 single-phase inverter features a thoughtfully optimised design tailored for modern energy systems. With a plug-and-play communication terminal, rapid 10-second data refresh intervals, and built-in I-V curve diagnosis, this inverter offers seamless setup and real-time performance visibility.

Product Advantage

Equipped with 3 MPP trackers for flexible panel orientation and support for up to 200% PV oversizing and 110% AC overloading, this inverter delivers superior power yield. With a built-in global MPP scan and 20A PV input current capacity, it's designed to maximise energy production in all conditions.

Assured Safety

  • Type II SPD on AC&DC side 

  • Ready for Rapid Shutdown function 

  • AFCI support (optional)

Flexible Adaptability

  • Supports parallel operation for up to 5 inverters, no  external EMS required 

  • Smart loads management (e.g., heat pump, smart EV  charger)

Intelligent Design

  • Plug-and-Play communication terminal 

  • 10s data refresh on SolaXCloud

  • IV curve scan

High Efficiency

  • 3 MPP trackers for multi-orientation 

  • Max. 20A PV input current 

  • 200% PV oversizing & 110% AC overloading 

  • Built-in global MPP scan

Product Parameters

  • X1-SMT-10K-G2
  • X1-SMT-9K-G2
  • X1-SMT-8K-G2
  • X1-SMT-7K-G2
  • X1-SMT-6K-G2
  • X1-SMT-5K-G2
  • X1-SMT-10K-G2
    • PV INPUT
      Max.recommended PV arraypower20 kWp
      Operation voltage range35 ~ 600 V
      No. of MPP trackers / strings per MPP tracker3 / (1 / 1 / 1)
      Max. input current per MPPT20 A / 20 A / 20 A


    • AC OUTPUT
      Rated output power9999 W
      Rated AC voltage1 / N / PE, 220 / 230 / 240 V


    • GENERAL
      Ingress protectionIP66
      Dimensions (W /H / D)

      515 × 370 × 170 mm

      Net Weight19.5 kg
      Cooling conceptNature cooling


  • X1-SMT-9K-G2
    • PV INPUT
      Max.recommended PV arraypower18 kWp
      Operation voltage range35 ~ 600 V
      No. of MPP trackers / strings per MPP tracker3 / (1 / 1 / 1)
      Max. input current per MPPT20 A / 20 A / 20 A


    • AC OUTPUT
      Rated output power9000 W
      Rated AC voltage1 / N / PE, 220 / 230 / 240 V


    • GENERAL
      Ingress protectionIP66
      Dimensions (W /H / D)

      515 × 370 × 170 mm

      Net Weight19.5 kg
      Cooling conceptNature cooling


  • X1-SMT-8K-G2
    • PV INPUT
      Max.recommended PV arraypower16 kWp
      Operation voltage range35 ~ 600 V
      No. of MPP trackers / strings per MPP tracker3 / (1 / 1 / 1)
      Max. input current per MPPT20 A / 20 A / 20 A


    • AC OUTPUT
      Rated output power8000 W
      Rated AC voltage1 / N / PE, 220 / 230 / 240 V


    • GENERAL
      Ingress protectionIP66
      Dimensions (W /H / D)

      515 × 370 × 170 mm

      Net Weight19.5 kg
      Cooling conceptNature cooling


  • X1-SMT-7K-G2
    • PV INPUT
      Max.recommended PV arraypower14 kWp
      Operation voltage range35 ~ 600 V
      No. of MPP trackers / strings per MPP tracker3 / (1 / 1 / 1)
      Max. input current per MPPT20 A / 20 A / 20 A


    • AC OUTPUT
      Rated output power7000 W
      Rated AC voltage1 / N / PE, 220 / 230 / 240 V


    • GENERAL
      Ingress protectionIP66
      Dimensions (W /H / D)

      515 × 370 × 170 mm

      Net Weight19.5 kg
      Cooling conceptNature cooling


  • X1-SMT-6K-G2
    • PV INPUT
      Max.recommended PV arraypower12 kWp
      Operation voltage range35 ~ 600 V
      No. of MPP trackers / strings per MPP tracker3 / (1 / 1 / 1)
      Max. input current per MPPT20 A / 20 A / 20 A


    • AC OUTPUT
      Rated output power6000 W
      Rated AC voltage1 / N / PE, 220 / 230 / 240 V


    • GENERAL
      Ingress protectionIP66
      Dimensions (W /H / D)

      515 × 370 × 170 mm

      Net Weight19.5 kg
      Cooling conceptNature cooling


  • X1-SMT-5K-G2
    • PV INPUT
      Max.recommended PV array power10 kWp
      Operation voltage range35 ~ 600 V
      No. of MPP trackers / strings per MPP tracker3 / (1 / 1 / 1)
      Max. input current per MPPT20 A / 20 A / 20 A


    • AC OUTPUT
      Rated output power4999 W
      Rated AC voltage1 / N / PE, 220 / 230 / 240 V


    • GENERAL
      Ingress protectionIP66
      Dimensions (W /H / D)

      515 × 370 × 170 mm

      Net Weight19.5 kg
      Cooling conceptNature cooling


Data Download

  • Datasheet
  • User Manual
  • Quick Installation Guide
English
  • File name
    Language
    Format
    Size
    Last updated
    download
To the Latest Newsletter

To the Latest Newsletter

Stay Ahead with the Latest SolaX Updates!

I have read and agree to Privacy Policy and User Terms

Subscribe to our Newsletter
  • *

    I have read and agree to Privacy Policy and User Terms

  • Submit
We Value Your Privacy

We use cookies to enhance your browsing experience, serve personalised content, and analyse site usage. By clicking "Accept All", you consent to our use of cookies. For more information, read ourCookie.